Finden Sie schnell kabel vorkonfektioniert für Ihr Unternehmen: 124 Ergebnisse

RE-2Y(St)HSWAH & RE-2X(St)HSWAH-MP

RE-2Y(St)HSWAH & RE-2X(St)HSWAH-MP

HALOGEN-FREE INSTRUMENTATION CABLES, EN 50288-7RE-2Y(St)HSWAH,SINGLE & MULTI-PAIR, PE INSULATED, COLLECTIVE SCREENED, ARMOURED, HFFR SHEATHEDRE-2X(St)HSWAH,SINGLE & MULTI-PAIR, XLPE INSULATED, COLLECTIVE SCREENED, ARMOURED, HFFR SHEATHED Insulation (2X): XLPE compound, EN 50290-2-29; (RE-2X….) Core identification: Black / White cores numbered 1-1, 2-2,…, Upon request ; Colour coded according to IEC 60189-2, Other core configurations manufactured upon request. Pair: Two conductors twisted to a pair Lay-up: Pairs laid up in layers of optimum pitch Separator: Polyester tape Screen: AL-PES tape over stranded tinned copper drain, wire 0,50 mm2 Inner sheath: HFFR compound, EN 50290-2-27 Armour: Galvenized round steel wire, EN 10257-1 Outer sheath: HFFR compound, EN 50290-2-27 Sheath colour: RAL 9005, Black or RAL 5015, Blue Conductor: Plain copper wire, stranded, IEC 60228 Sınıf 2, TS/DIN EN 60228 Sınıf 2 Insulation (2Y): PE compound, EN 50290-2-23; (RE-2Y….) Standard: TS/DIN EN 50288-7 Insulation thickness: 0,50mm2 : 0,40 mm, 0,75mm2 : 0,40 mm, 1,0mm2 : 0,40 mm, 1,3mm2 : 0,45 mm, 1,5mm2 : 0,45 mm Conductor resistance: 0,50mm2 : 36,7 Ω/km, 0,75mm2 : 25,0 Ω/km, 1,0mm2 : 18,5 Ω/km, 1,3mm2 : 14,2 Ω/km, 1,5mm2 : 12,3 Ω/km Insulation resistance: Min. 5000 MΩ.km Capacitance unbalance: (1 kHz) : max. 500 pF/500 m L / R (ratio) (max.): 0,50mm2 : 25 µH/Ω, 0,75mm2 : 25 µH/Ω, 1,0mm2 : 25 µH/Ω1,30mm2 : 40 µH/Ω, 1,5mm2 : 40 µH/Ω Rated voltage: 300V Test voltage: Urms core-core : 1500 V, Urms core-screen : 1500 V Temperature range (2Y): operation : - 30 oC ~ + 70 oC, ınstallation : - 5 oC ~ + 50 oC Temperature range (2X): operation : - 30 oC ~ + 90 oC, ınstallation : - 5 oC ~ + 50 oC Min. bending radius: 10 x D Flame test: IEC 60332-1 & TS/DIN EN 60332-1, IEC 60332-3 & TS/DIN EN 50266-2-4 Smoke density test: IEC 61034-2 & TS/DIN EN 61034-2 Halogen-free properties test: IEC60754-1/2 & TS/DIN EN 50267-2
RE-2Y(St)HSWAH&RE-2X(St)HSWAH-MP

RE-2Y(St)HSWAH&RE-2X(St)HSWAH-MP

HALOGEN-FREE INSTRUMENTATION CABLES, Acc. to BS 5308 PART 1 TYPE 2RE-2Y(St)HSWAH,SINGLE & MULTI-PAIR, PE INSULATED, COLLECTİVE SCREENED, ARMOURED, LSZH SHEATHEDRE-2X(St)HSWAH,SINGLE & MULTI-PAIR, XLPE INSULATED, COLLECTİVE SCREENED, ARMOURED, LSZH SHEATHED These cables are used for transmission of analoge and digital signals in instrument and control systems at chemistry and petrochemistry industry plants, power plants, natural gas and petroluem plants, etc... . Instrumentation cables are not allowed for direct connection to a low impedance sources, e.g. public mains electricity supply. In case of fire, these cables inhibit the propagation of the flames whereby the development of smoke is extremely low. No corrosive gases are emitted in the event of fire. With blue sheath it is suitable for intrinsically safe systems. The armour above the inner sheath protects the cable from mechanical shocks. These cables are recommended for direct burial. They are for indoor and oudoor installation, in dry and wet locations; on racks, trays, in conduits. Insulation (2X): XLPE compound, GP8, BS 7655 (RE-2X….) Core identification: According to BS 5308 Part 1 colour coded , Note: Other core configurations manufactured upon request Pair: Two conductors twisted to a pair Lay-up: Pairs laid up in layers of optimum pitch Separator: Polyester tape Screen: AL-PES tape over tinned copper drain wire 0,50 mm2 Bedding: LSZH compound, Black Armour: Galvenized round steel wire, BS EN 10257-1 Outer sheath: LSZH compound, LST1, BS 7655, LSZH : Low Smoke Zero Halogen Sheath colour: RAL 9005, Black or RAL 5015, Blue Conductor: Plain annealed copper wire, BS 6360, 0,50 mm2 and 1,0 mm2 solid, 0,50 mm2 and, 0,75 mm2 flexible or 1,5 mm2 stranded Insulation (2Y): PE compound, BS 6234 Type03 (RE-2Y….) Standard: Designed acc. to BS 5308 Part 1 Type 1 Insulation thickness: 0,50mm2 : 0,50mm, 1,0mm2 : 0,60mm, 0,50mm2 : 0,60mm, 0,75mm2 : 0,60mm, 1,50mm2 : 0,60mm Conductor class, BS 6360: 0,50mm2 : Class 1, 1,0mm2 : Class 1, 0,50mm2 : Class 5, 0,75mm2 : Class 5, 1,5mm2 : Class 2 Conductor resistance: 0,50mm2 : 36,8 Ω/km, 1,0mm2 : 18,4 Ω/km, 0,50mm2 : 39,7 Ω/km, 0,75mm2 : 26,5 Ω/km, 1,5mm2 : 12,3 Ω/km Insulation resistance: Min. 5000 MΩ.km Capacitance unbalance: (1 kHz) : max. 250 pF/250 m L / R (ratio) (max.): 0,50mm2 : 25 µH/Ω, 0,75mm2 : 25 µH/Ω, 1,0mm2 : 25 µH/Ω1,5mm2 : 40 µH/Ω Rated voltage: 300/500V Test voltage: Urms core-core : 1000 V, Urms core-screen : 1000 V Temperature range (2Y): operation : - 40 oC ~ + 70 oC, ınstallation : - 5 oC ~ + 50 oC Temperature range (2X): operation : - 40 oC ~ + 90 oC, ınstallation : - 5 oC ~ + 50 oC Min. bending radius: 8 x D Flame retardance test: IEC 60332-1 & BS EN 60332-1, IEC 60332-3 & BS EN 50266-2-4 Smoke density test: IEC 61034-2 & BS EN 61034-2 Halogen-free properties test: IEC60754-1/2 & BS EN 50267-2
RE-2Y(St)HSWAH-TIMF & RE-2X(St)HSWAH-TIMF

RE-2Y(St)HSWAH-TIMF & RE-2X(St)HSWAH-TIMF

HALOGEN-FREE INSTRUMENTATION CABLES, EN 50288-7RE-2Y(St)HSWAH-TIMF,MULTI-TRIPLE, PE INSULATED, INDIVIDUAL & COLLECTIVE SCREENED, ARMOURED, HFFR SHEATHEDRE-2X(St)HSWAH-TIMF,MULTI-TRIPLE, XLPE INSULATED, INDIVIDUAL & COLLECTIVE SCREENED, ARMOURED, HFFR SHEATHED These cables are used for transmission of analoge and digital signals in instrument and control systems at chemistry and petrochemistry industry plants, power plants, natural gas and petroluem plants, etc... These cables are used in the environments which have no corrosive gases are emitted in the event of fire. In case of fire, these cables inhibit the propagation of the flames whereby the development of smoke is extremely low. Instrumentation cables are not allowed for direct connection to a low impedance sources, e.g. public mains electricity supply. With blue sheath it is suitable for intrinsically safe systems. The armour above the inner sheath protects the cable from mechanical shocks. These cables are recommended for direct burial. They are for indoor and outdoor installation, in dry and wet locations; on racks, trays, in conduits. Conductor: Plain copper wire, stranded, IEC 60228 Sınıf 2, TS/DIN EN 60228 Sınıf 2 Insulation (2Y): PE compound, EN 50290-2-23; (RE-2Y….) Insulation (2X): XLPE compound, EN 50290-2-29; (RE-2X….) Core identification: Black / Beyaz / Red; with numbered tape under, separator tape of the pair screen, Upon request ; Black / White / Red cores numbered 1-1-1, 2-2-2,…, Other core configurations manufactured upon request. Triple: Three conductors twisted to a triple TIMF Construction: Polyester tape above the triple, AL-PES tape, over solid tinned copper drain wire, 0,60 mm, Upon request ; Stranded 0,50 mm2 copper drain wire Lay-up: TIMF laid up in layers of optimum pitch Separator: Polyester tape Screen: AL-PES tape over stranded tinned copper drain, wire 0,50 mm2 Inner sheath: HFFR compound, EN 50290-2-27 Armour: Galvenized round steel wire, EN 10257-1 Outer sheath: HFFR compound, EN 50290-2-27 Sheath colour: RAL 9005, Black or RAL 5015, Blue Standard: TS/DIN EN 50288-7 Insulation thickness: 0,50mm2 : 0,40 mm, 0,75mm2 : 0,40 mm, 1,0mm2 : 0,40 mm, 1,3mm2 : 0,45 mm, 1,5mm2 : 0,45 mm Conductor resistance: 0,50mm2 : 36,7 Ω/km, 0,75mm2 : 25,0 Ω/km, 1,0mm2 : 18,5 Ω/km, 1,3mm2 : 14,2 Ω/km, 1,5mm2 : 12,3 Ω/km Insulation resistance: Min. 5000 MΩ.km Mutual Capacitance: max. 120 pF/m L / R (ratio) (max.): 0,50mm2 : 25 µH/Ω, 0,75mm2 : 25 µH/Ω, 1,0mm2 : 25 µH/Ω1,30mm2 : 40 µH/Ω, 1,5mm2 : 40 µH/Ω Rated voltage: 300V Test voltage: Urms core-core : 1500 V, Urms core-screen : 1500 V Temperature range (2Y): operation : - 30 oC ~ + 70 oC, ınstallation : - 5 oC ~ + 50 oC Temperature range (2X): operation : - 30 oC ~ + 90 oC, ınstallation : - 5 oC ~ + 50 oC Min. bending radius: 10 x D Flame test: IEC 60332-1 & TS/DIN EN 60332-1, IEC 60332-3 & TS/DIN EN 50266-2-4 Smoke density test: IEC 61034-2 & TS/DIN EN 61034-2 Halogen-free properties test: IEC60754-1/2 & TS/DIN EN 50267-2
RE-2Y(St)HSWAH-TIMF&RE-2X(St)HSWAH-TIMF

RE-2Y(St)HSWAH-TIMF&RE-2X(St)HSWAH-TIMF

HALOGEN-FREE INSTRUMENTATION CABLES, Acc. to BS 5308 PART 1 TYPE 2RE-2Y(St)HSWAH-TIMF,SİNGLE & MULTİ-TRIPLE, PE INSULATED, INDIVIDUAL & COLLECTİVE SCREENED, ARMOUR, LSZH SHEATHEDRE-2X(St)HSWAH-TIMF,SİNGLE & MULTİ-TRIPLE, XLPE INSULATED, INDIVIDUAL & COLLECTİVE SCREENED,ARMOUR, LSZH SHEATHED These cables are used for transmission of analoge and digital signals in instrument and control systems at chemistry and petrochemistry industry plants, power plants, natural gas and petroluem plants, etc... . Instrumentation cables are not allowed for direct connection to a low impedance sources, e.g. public mains electricity supply. In case of fire, these cables inhibit the propagation of the flames whereby the development of smoke is extremely low. No corrosive gases are emitted in the event of fire. With blue sheath it is suitable for intrinsically safe systems. The armour above the inner sheath protects the cable from mechanical shocks. These cables are recommended for direct burial. They are for indoor and oudoor installation, in dry and wet locations; on racks, trays, in conduits. Conductor: Plain annealed copper wire, BS 6360, 0,50 mm2 and 1,0 mm2 solid, 0,50 mm2 and, 0,75 mm2 flexible or 1,5 mm2 stranded Insulation (2Y): PE compound, BS 6234 Type03 (RE-2Y….) Insulation (2X): XLPE compound, GP8, BS 7655 (RE-2X….) Core identification: Black / White / Red; with numbered tape under, separator tape of the pair screen, *Upon request ; Black / White / Red cores numbered 1-1-1, 2-2-2,… Triple: Three conductors twisted to a triple TIMF Construction: Polyester tape above the triple, AL-PES tape, over tinned copper drain wire, 0,50 mm2 Lay-up: TIMF laid up in layers of optimum pitch Separator: Polyester tape Screen: AL-PES tape over tinned copper drain wire 0,50 mm2 Bedding: LSZH compound, Black Armour: Galvenized round steel wire, BS EN 10257-1 Outer sheath: LSZH compound, LST1, BS 7655 Sheath colour: RAL 9005, Black or RAL 5015, Blue Standard: Designed acc. to BS 5308 Part 1 Type 1 Insulation thickness: 0,50mm2 : 0,50mm, 1,0mm2 : 0,60mm, 0,50mm2 : 0,60mm, 0,75mm2 : 0,60mm, 1,50mm2 : 0,60mm Conductor class, BS 6360: 0,50mm2 : Class 1, 1,0mm2 : Class 1, 0,50mm2 : Class 5, 0,75mm2 : Class 5, 1,5mm2 : Class 2 Conductor resistance: 0,50mm2 : 36,8 Ω/km, 1,0mm2 : 18,4 Ω/km, 0,50mm2 : 39,7 Ω/km, 0,75mm2 : 26,5 Ω/km, 1,5mm2 : 12,3 Ω/km Insulation resistance: Min. 5000 MΩ.km Mutual Capacitance: 0,50 mm2 : max. 115 pF/m, 0,75 mm2 : max. 115 pF/m, 1,0 mm2 : max. 115 pF/m, 1,5 mm2 : max. 120 pF/m Capacitance unbalance: (1 kHz) : max. 250 pF/250 m L / R (ratio) (max.): 0,50mm2 : 25 µH/Ω, 0,75mm2 : 25 µH/Ω, 1,0mm2 : 25 µH/Ω1,5mm2 : 40 µH/Ω Rated voltage: 300/500V Test voltage: Urms core-core : 1000 V, Urms core-screen : 1000 V Temperature range (2Y): operation : - 40 oC ~ + 70 oC, ınstallation : - 5 oC ~ + 50 oC Temperature range (2X): operation : - 40 oC ~ + 90 oC, ınstallation : - 5 oC ~ + 50 oC Min. bending radius: 8 x D Flame retardance test: IEC 60332-1 & BS EN 60332-1, IEC 60332-3 & BS EN 50266-2-4 Smoke density test: IEC 61034-2 & BS EN 61034-2 Halogen-free properties test: IEC60754-1/2 & BS EN 50267-2